Installation Instructions

Important Installation Instructions:

For structural applications requiring building code compliance such as post-frame construction, interior or exterior support columns etc.:
A minimum of 8" must be exposed from the top of the POSTSAVER® boot to the top of the exposed earth ("ground level"). If a concrete slab is installed, a minimum of 2" must be exposed from the top of the POSTSAVER® boot to the top of the concrete surface line.

For non-structural applications such as fence posts, mailbox posts, sign posts etc.:
A minimum of 2" must be exposed from the top of the POSTSAVER®
boot to the top of the exposed earth ("ground level") or concrete surface line.

Important:  Never puncture or cut a Postsaver® boot or sleeve. POSTSAVER® boot repair.

Penetration of the boot material below “ground level” on the post by fasteners, bolts and nails is not permitted. 

Fastener penetration into the boot material is permitted 2" above the "ground level" on the post provided there is no direct exposure to weather.